Testing acc. to ISO 19070: Leather - Chemical determination of N-ethyl-2-pyrrolidone (NEP) in leather

Our test laboratory performs testing according to DIN EN ISO 19070 (NEP) using an accredited method for the quantitative determination of N-ethyl-2-pyrrolidone (NEP) in leather. The substance is extracted from the material using a defined solvent extraction procedure and subsequently quantified by gas chromatography-mass spectrometry (GC-MS). The test enables the specific detection of NEP as a residual solvent and provides important information for chemical material characterisation and the assessment of potentially harmful substances.

N-ethyl-2-pyrrolidone belongs to the group of polar aprotic solvents and may be used in the manufacture and processing of polymer coatings. Residues can be particularly relevant in finished leather, synthetic leather and coated materials. Due to the health-related concerns associated with this substance, quantitative determination is important for assessing material quality and product safety.

Test Procedure According to DIN EN ISO 19070 (NEP)

During testing, a prepared leather specimen is extracted with acetone in an ultrasonic bath at a temperature of 50 °C for one hour. This process transfers the NEP contained in the material into the extraction solvent.

The extract is subsequently prepared and analysed using GC-MS. Chromatographic separation and mass-selective detection enable the identification and quantitative determination of NEP. Evaluation is based on suitable analyte-specific calibration.

The measured NEP concentration is expressed in mg/kg relative to the mass of the tested specimen. The method determines the amount of the substance extractable under the specified conditions. It does not directly measure emissions or the actual release of NEP under conditions of use.

Applications of the Test

Testing according to DIN EN ISO 19070 (NEP) enables the quantitative assessment of N-ethyl-2-pyrrolidone as an undesirable residual solvent in leather and leather components. Differences in coating formulations, solvents used, manufacturing processes and drying conditions can influence the remaining NEP content and can be characterised by this test.

Typical applications include finished leather used for footwear, clothing, upholstered furniture and automotive interiors. The results support material development, incoming goods inspection, quality assurance and the verification of specified requirements concerning solvent residues.

The specific determination of NEP is also relevant for evaluating coating processes and selecting suitable raw materials. Similar investigations may be useful for synthetic leather, coated textiles and other polymer materials, provided that the applicability of the test method to the respective material is considered.

Related Tests

For additional investigation of residual solvents, FILK offers accredited testing for N-methyl-2-pyrrolidone (NMP) according to DIN EN ISO 19070 (NMP). While the method described here specifically determines NEP, the related test is intended for the determination of NMP. Both substances belong to the group of cyclic lactams and may be used as solvents in polymer processing.

For the determination of selected aprotic solvent residues in textiles and textile coatings, FILK also offers testing according to DIN EN 17131-1. This method covers NMP, NEP, dimethylformamide (DMF) and dimethylacetamide (DMAc). Further analytical methods are summarised in the Solvent Residues section.

Further information on testing for organic harmful substances is available in our Organic Harmful Substances overview. A comprehensive overview of our analytical testing methods is provided in the Chemical Analysis section. Our complete range of testing services can be found in the Accredited Test Laboratory overview.