TESLA TP-0000912 Emissions Behavior

Testing accordíng TP-0000912: Emissions Behavior of Materials

Our test laboratory performs accredited testing according to Tesla TP-0000912 for the determination of the emission behaviour of automotive interior materials.

The Tesla test specification TP-0000912 – Test Procedure: Emissions Behavior of Materials describes a standardized method for evaluating volatile organic compounds (VOC), carbonyl compounds, fogging behaviour and odour of non-metallic materials. The test is based on the established standards ISO 12219-3, ISO 6452 (gravimetric fogging method) and VDA 270, and is particularly applicable to plastics, synthetic leather, leather, textiles, foams, adhesives and other automotive interior materials. It is used to ensure low emissions and high interior air quality in vehicles.

Test Procedure

For testing, the specimens are conditioned under defined environmental conditions and subsequently examined in accordance with the respective reference standards. VOC emissions are determined according to ISO 12219-3 using a micro-scale emission chamber, followed by the analysis of volatile organic compounds and carbonyl compounds. In addition, fogging behaviour is determined according to ISO 6452 using the gravimetric method, while odour is assessed according to VDA 270 under both dry and humid conditions. The results are reported as area-specific or mass-specific emission rates, fogging condensate mass, and odour ratings.

Relationship to Other Standards

Tesla TP-0000912 complements other emission and vehicle interior test methods offered by the FILK testing laboratory. While standards such as ISO 12219-3, ISO 6452 and VDA 270 each address a specific aspect—VOC emissions, fogging or odour—Tesla TP-0000912 combines these evaluations within a single material specification for automotive interior materials. This provides a comprehensive assessment of the emission characteristics of materials in accordance with Tesla's material requirements.

An overview of our currently available Tesla test services can be found here.